On this page
- What does “soundproof flooring” actually mean?
- Why does a concrete slab behave differently from timber joists?
- Is soundproofing a house floor different from an apartment floor?
- How should you compare floor types for impact noise?
- Why does the underlay do most of the work on a slab?
- How do you soundproof an existing floor without replacing it?
- Rugs and runners
- Refit the underlay under a floating floor
- When the answer is the ceiling in the unit below
- What can you do about noise from upstairs neighbours?
- What actually helps in a timber joist house?
- How do you get comparable quotes?
- What should you ask a supplier or builder?
Quiet at home might mean fewer heel clicks in a living room or less footfall reaching the bedroom below. Those are different problems, even when they start at the same floor.
There is no floor finish that makes a room silent. Start with the noise you hear and the structure carrying it. Then choose the floor, underlay and installation details that address that path.
What does “soundproof flooring” actually mean?
Noise gets into the room below in two ways. Impact noise starts when something hits the floor: footsteps, a dropped pan, a chair dragged across boards. The hit makes the structure vibrate, and the ceiling below gives that vibration off as sound. Airborne noise starts as sound in the air, such as voices, TV and music, and has to push its way through the floor or walls.
The two need different fixes. The ABCB sound handbook (Appendix B.2) says structure-borne sound “cannot be attenuated by barriers or walls but requires the isolation of the vibration itself”, using “a resilient element such as rubber, neoprene or springs”. Carpet and acoustic underlay are resilient elements. For airborne noise the handbook (section 3.4.1) points to mass: added mass is “particularly effective in reducing airborne noise”.
So a floor mostly fixes the first problem and barely touches the second: an underlay and a floor finish weigh very little next to a concrete slab. The Australasian Timber Flooring Association (ATFA) says noise from talking and televisions “is controlled by mass of the floor system”, and that over a concrete slab “the mass of the slab generally provides sufficient control for this not to be a problem”. Footsteps are the hard part, because they vibrate “the whole structure including the slab and walls”.
Spec sheets and by-laws use a few ratings. Ln,w is impact noise through a floor measured in a laboratory, and L’nT,w (often written LnT,w) is impact noise measured in a real building; for both, lower is quieter. ΔLw is how much an underlay improves a standard bare floor in a laboratory; higher is better. Rw + Ctr and DnT,w + Ctr are the airborne ratings, laboratory and on site, where higher is better. The impact figures are defined in AS ISO 717.2:2024 and used in NCC Part F7; see acoustic ratings explained for each one.
Why does a concrete slab behave differently from timber joists?
On a concrete slab, the slab’s weight stops most airborne noise. Footsteps are the problem: a hard finish fixed straight to the slab passes each impact into the concrete, and a thicker slab helps but does not solve it. In a 2014 South-East Queensland field study, bare 180 mm slabs with no ceiling measured L’nT,w 68 to 76 on site, and bare 200 mm slabs measured 65 to 69. Both are worse than the NCC’s on-site limit of 62, so a bare slab needs something resilient on top or a ceiling underneath.
On timber joists, the structure is light. There is little mass to stop airborne noise, and footsteps travel through the boards and joists themselves. The ABCB handbook (section 3.2.2) recommends a break in the floorboards and joists between units to “control structure-borne noise intrusion from footsteps”, which shows how readily the frame carries them. So a timber floor needs work on both kinds of noise, mostly below the boards.
The AAAC explanatory note (May 2023) makes the same point: a test of a hard timber floor on acoustic underlay above a concrete slab “will be very different” to the same floor and underlay above “a joisted timber floor with plasterboard ceiling”. Never use a slab test to choose a floor for a timber-framed building, or the other way round.
Is soundproofing a house floor different from an apartment floor?
Yes. You are protecting different people, and only one of them has the law behind them.
In a house, the floor usually sits over your own living room or bedroom. The NCC’s sound rules for houses are in Volume Two, and the ABCB handbook (section 2.5) says they cover walls separating attached dwellings, such as townhouses. They set no sound rating for the floors inside your own home. You set the target, and you decide what is worth the money.
In an apartment, you are protecting a neighbour, and a code and a by-law stand behind them. Clause F7D5 of NCC 2022 Volume One says a floor between sole-occupancy units in a Class 2 or 3 building must have “an Rw + Ctr (airborne) not less than 50 and an Ln,w (impact) not more than 62”. Those are laboratory figures. The performance requirement in clause F7P1 sets on-site figures: a DnT,w + Ctr of at least 45 and an L’nT,w of no more than 62. NCC 2025 keeps the same figures.
Extra sound transmission possible when carpet is replaced by a hard floor
Source: ABCB sound handbook, section 5.1.1The code is a minimum, not a target. Queensland’s appeal tribunal said in McLeod v Body Corporate for Stradbroke Tower and Villas [2015] QCATA 146 at [29] that the BCA “is a minimum construction standard” and “does not set levels for the purposes of good neighbourly relations”. Many buildings write a stricter figure into their by-laws, often in AAAC star terms. The AAAC guideline sets on-site impact figures of L’nT,w below 55 for 3 star, below 50 for 4 star, below 45 for 5 star and below 40 for 6 star, so the NCC’s 62 sits between 2 and 3 stars. Your building’s figure is in its by-laws; our strata flooring rules guides explain them state by state. Whether replacing a floor finish in an existing apartment must itself meet Part F7 is a question for a building certifier; the by-laws apply either way.
How should you compare floor types for impact noise?
The table compares floor constructions and evidence to request. Published examples come from different buildings and assemblies; they do not rank material categories or predict a result for your home. Keep each metric, construction and limitation beside the number.
For scale, the ABCB handbook (section 5.1.1) says replacing carpet with a hard floor “can result in as much as 25 to 30 dB extra sound transmission”, and the AAAC guideline puts 3 star at L’nT,w below 55, 4 star below 50 and 5 star below 45.
| Floor | What does the work | Published example or evidence to request | Best for | Watch-outs |
|---|---|---|---|---|
| Carpet on underlay | Soft pile and underlay absorb each footstep before it reaches the slab | L'nT,w 33 on a 180 mm slab (QCATA 2017). NCC deemed-to-satisfy on a 200 mm slab (Specification 28) | Bedrooms, and buildings with strict by-laws | Hard to match with any hard floor, which is why many by-laws are written around it |
| Engineered timber floating on rubber underlay | Resilient underlay isolates the boards from the slab; the floor touches no wall | L'nT,w 41 to 52 for six floating timber and bamboo systems on a 180 mm slab (QCATA 2017) | Living areas where a by-law asks for 4 or 5 star | Thicker, denser boards flex less and do worse (ATFA). Keep a gap at every wall and skirting |
| Hybrid with attached pad | A thin pad bonded to the rigid core | Require a complete report for the proposed construction; the product category does not supply a result | Rooms where the proposed system is accepted and supported by relevant evidence | Compare the tested slab, ceiling, backing and fixing method with the proposed floor |
| Hybrid with separate underlay | A separate acoustic underlay under the hybrid | Depends on the system, ask for the test | When the attached pad alone does not reach the by-law figure | Get both the flooring maker and the underlay maker to accept the combination in writing |
| Timber glued on rubber underlay | A rubber layer between the fixed boards and the slab | Depends on the system, ask for the test | Solid or engineered timber that must be fixed down | Nails or screws through the rubber bridge it (ABCB 4.4). Solid timber often needs a plywood layer (ATFA) |
| Laminate on foam underlay | Thin foam under a thin board | On site: 51 and 54 on foam (NCAT, Jiang v Sui 2023); 60 and 61 on a 2 mm acoustic underlay (NCAT, Kim 2023) | Rooms in a house with nobody below | In both cases a supplier certificate promised a better figure than the finished floor achieved |
| Tile on acoustic mat | A mat under the tile bed isolates the rigid tile from the slab | L'nT,w 52 to 65 on a 190 mm slab with no ceiling; 44 to 51 with a plasterboard ceiling below (Inter-noise 2014) | Kitchens and wet areas | Tiles barely flex, so the mat has a hard job (ATFA). Tiles or grout touching walls bridge it |
| Vinyl sheet | A thin, soft wear layer, plus any underlay | Depends on the system, ask for the test | Wet areas where carpet is not practical | The published figures we found are for vinyl planks and tiles, not sheet |
| Bare tile on slab | Nothing: the tile passes each hit straight into the slab | 0 to 2 points better than the bare slab (Inter-noise 2014); L'nT,w 75 to 80 on site in one Queensland scheme (18 Kingsford Street, 2016) | Nowhere above another home | Queensland adjudicators have ordered floors like this covered or replaced |
Sources: the carpet and floating timber results are from a Brisbane tower, set out in Body Corporate for Admiralty Towers II v Johnson [2017] QCATA 29 at [12]. The deemed carpet floor is clause S28C8(3) of Specification 28. The laminate results come from Jiang v Sui [2023] NSWCATCD 127 and The Owners Strata Plan No 7704 v Kim [2023] NSWCATCD 39. The tile and bare-tile results come from the Inter-noise 2014 study, which also found vinyl of 3 to 9 mm on underlay improved on the bare slab by 8 to 21 points, and from 18 Kingsford Street [2016] QBCCMCmr 78. The board and tile notes are from the ATFA information sheet.
Choosing for an apartment? See the best flooring for apartments and acoustic hybrid flooring.
Why does the underlay do most of the work on a slab?
On a slab, the concrete already handles airborne noise. The job left is to stop impacts reaching the concrete, and the underlay is the only resilient layer in the build-up. In the Inter-noise 2014 study, floating timber on underlay improved on the bare slab by 15 to 22 points, while tile stuck straight to the slab improved it by 0 to 2.
Underlay data sheets usually quote ΔLw. Under AS ISO 717.2:2024, the Australian adoption of ISO 717-2, it is the difference in impact level on a standard bare heavy reference floor without and with the covering, measured in a laboratory, and higher is better. It is good for comparing underlays, but it is not your floor’s rating, and you cannot subtract it from your building’s figure: in the Inter-noise 2014 case study, the same five underlays improved a bare slab by 4 to 17 points with no ceiling, but by 4 to 11 points once a plasterboard ceiling was added. The AAAC explanatory note goes further: no single product, “especially an acoustic underlay”, is guaranteed to reach a rating or star level on its own.
Installation matters as much as the product. The ABCB handbook (section 4.4) warns that nails and screws through a rubber underlay “diminish its performance”, and that isolated floors “should not be installed in contact with side walls”. Our acoustic underlay guide compares types by floor.
How do you soundproof an existing floor without replacing it?
Rugs and runners
A thick rug on a rug underlay softens footsteps where people walk most. The ATFA information sheet lists rugs and runners in high-traffic areas, and soft-soled footwear, among factors that “can have a profound effect on the actual noise transferred”. The limit is coverage: hallways, kitchens and room edges stay hard. In Beau Monde [2011] QBCCMCmr 548, a Queensland adjudicator ordered rugs on the walked tiled areas within 30 days, and also ordered the owner to take sufficient steps within six months, including replacing the tiles or laying carpet and underlay over them if necessary. Rugs are a first step, not the fix.
Refit the underlay under a floating floor
A floating floor is not glued or nailed to the slab, so the underlay under it can be changed. If it sits on thin foam, an installer can lift the boards, lay a tested acoustic underlay and relay them, with a gap at every wall. Whether the boards survive being lifted depends on the product, so check with the installer and the maker first. Ask for a test on a build-up close to yours, because the ATFA says the same underlay gives different results under different floors. Thin underlay is a common weak point: in Sui v Jiang [2024] NSWCATAP 128, the appeal panel noted evidence that the underlay under the disputed laminate was only about 2 to 3 mm thick.
A glued floor or tiles have no underlay to swap. The options a Queensland adjudicator gave in 18 Kingsford Street were carpet and underlay over the tiles, carpet and underlay instead of the tiles, or “new tiles laid over an appropriate acoustic membrane”.
When the answer is the ceiling in the unit below
Sometimes the fix is underneath. The ABCB handbook (section 5.1.1) says the extra noise from swapping carpet for a hard floor “is difficult to reduce, and the use of resilient suspended ceilings becomes an important part of any design solution”. A resilient ceiling hangs on isolation mounts instead of being fixed hard to the slab, with insulation in the cavity. The NCC’s own deemed floor in clause S28C8(2) of Specification 28 is a 150 mm slab with 13 mm plasterboard on furring channels and isolation mounts, and 65 mm polyester insulation in the cavity.
In the Inter-noise 2014 case study, one layer of 13 mm plasterboard ceiling improved a bare 190 mm slab by 14 points, from L’nT,w 69 to 55. The handbook adds two warnings. Even with resilient ceilings and floors, a compliant system “may still transmit sound at 15 to 20 dB higher than the original carpet design”. And (section 5.1.2) a rated ceiling belongs in the original construction, because “there is no guarantee of access to the unit or dwelling underneath to retrofit later”. Downlights, air conditioning, vents and sprinklers each need acoustic treatment.
In an apartment, the ceiling is in the unit below and may not belong to either owner. Ask the body corporate or owners corporation in writing who owns it before anyone plans work.
What can you do about noise from upstairs neighbours?
Footsteps from upstairs are an impact noise problem, and impact noise is best controlled at its source: the floor finish and underlay in the unit above. That floor is the upstairs owner’s to fix. A ceiling on your side can help, but you cannot carry out work in their lot.
What you can do is use the rules. In NSW, section 153 of the Strata Schemes Management Act 2015 says an occupier must not use a lot in a way that “causes a nuisance or hazard to the occupier of any other lot”. In Queensland, section 167 of the Body Corporate and Community Management Act 1997 says an occupier must not use a lot in a way that “interferes unreasonably with the use or enjoyment of another lot”. Many schemes also have noise or floor coverings by-laws, and NSW Fair Trading and the Queensland body corporate commissioner set out a similar path:
- Talk to the neighbour, and keep a dated record of the noise.
- Ask the owners corporation or body corporate to act on the by-laws.
- Use the free mediation service in NSW, or conciliation in Queensland.
- Apply to NCAT in NSW, or for adjudication in Queensland.
Bring objective evidence. In Norbury v Hogan [2010] QCATA 27, the tribunal said the test is whether the activity would interfere unreasonably with “another lot owner of ordinary sensitivity”. In Felcher v The Owners Strata Plan No 2738 [2017] NSWCATAP 219, a complaint about a floating floor failed because the owner below provided “no expert evidence” and “no reports from an acoustic engineer or from a builder”. With a test, tribunals act: in Kim, NCAT ordered a laminate floor that missed its approval conditions treated to 50 LnT,w within 56 days. The strata flooring rules hub links to each state’s rules, including strata flooring rules in NSW and body corporate flooring rules in Queensland.
What actually helps in a timber joist house?
A timber-framed floor has no slab to lean on, so three things do the work, and they work together. All three come from the ABCB handbook.
- Mass. Heavier layers resist airborne noise. Section 3.4.1 says an extra skin, such as “an additional layer of plasterboard with a cavity”, can “effectively reduce sound transmission”, and that deeper cavities work better. In practice that means a thicker or doubled plasterboard ceiling.
- Decoupling. Break the path the vibration takes. Section 4.5.2 says that in timber construction “it is good practice to install walls and ceilings on isolation mounts to improve impact isolation between floors”. A resilient underlay decouples the floor from above; isolation mounts decouple the ceiling from below.
- Absorption. Insulation in the joist cavity soaks up sound. Section 3.4.2 says the sound insulation of “a lightweight building element can be improved by introducing sound absorption into cavities”, with materials such as glass wool, rock wool or polyester.
The NCC shows the three working together. Clause S28C10(2) of Specification 28 deems a floor of 19 mm particleboard on 190 x 45 mm joists, with R2.5 insulation, isolation mounts and two layers of 16 mm fire-protective plasterboard, to meet Rw + Ctr 50 and Ln,w 62. That is the apartment standard, reached with mass, decoupling and absorption instead of a slab. In a house most of this work happens from below, so the easiest time is when the ceiling is coming down anyway.
How do you get comparable quotes?
Ask for itemised quotes against the same scope so the difference between them is clear:
- Get at least three quotes for the same build-up: the same floor, the same underlay make and thickness, the same area.
- Ask each quote to itemise removal of the old floor, slab preparation and levelling, the underlay, perimeter isolation, skirtings and trims, and door trimming.
- Ask whether an on-site acoustic test is included, who carries it out, and what happens if the result misses the by-law figure.
- For a ceiling, ask for the mounts, insulation and plasterboard in writing, and how downlights and vents will be treated.
- Ask which figure the quote is built to: the NCC minimum, or the figure in your by-law.
What should you ask a supplier or builder?
- What impact rating does this floor achieve, and is it a laboratory Ln,w, an underlay ΔLw or an on-site L'nT,w?
- Can I see the full test report, not a brochure figure?
- What was the tested build-up: floor, underlay and its thickness, slab thickness, and the ceiling below?
- Who carried out the test, who paid for it, and is the lab NATA-accredited or the consultant an AAAC member firm?
- Does the test match my building: concrete slab or timber joists, and the same kind of ceiling below?
- Will you leave a gap at every wall and skirting, with no nails or screws through the underlay?
- Do the flooring maker and the underlay maker both accept this combination in writing, with warranties intact?
- Can we lay a sample and test it on site before the whole floor goes down?
- If the finished floor is tested and misses the required figure, what will you do?
The sample test is the AAAC’s own advice: its explanatory note calls installing a sample in situ and testing it “the commonly accepted acoustical method”, and says the finished floor should be tested for certainty.
If the sound is a click or creak within your own floor, start with the floor-noise diagnosis guide. If you need evidence of sound reaching another apartment, read about the post-installation acoustic test.
For a click or creak within your own floor, start with the floor-noise diagnosis guide. For evidence of sound reaching another apartment, read about the post-installation acoustic test.
Questions, answered
Does soundproof flooring stop voices and TV noise?
Mostly not. Voices and TV are airborne noise, and on a concrete slab the slab's weight already does most of the work against them. An underlay or soft floor finish mainly reduces noise from footsteps and other impacts. If you hear voices clearly through a slab, look for gaps, ducts, downlights and other openings, which the ABCB sound handbook lists as common flanking paths.
What is the best flooring to stop footstep noise?
In the published Australian field results we found (as at September 2026), carpet on underlay was clearly the quietest: L'nT,w 33 on a 180 mm slab in a Brisbane tower, against 41 to 52 for floating timber and bamboo systems in the same building (Body Corporate for Admiralty Towers II v Johnson [2017] QCATA 29). Among hard floors, the underlay and the installation matter more than the board.
Can I soundproof a floor from below?
Partly. A resilient suspended ceiling with insulation in the cavity can cut footstep noise a lot. In one published case study a single plasterboard ceiling improved a bare slab by 14 points. The ABCB handbook warns that the result may still be 15 to 20 dB worse than the original carpet, and in an apartment the ceiling is in someone else's home, so you need their agreement and the body corporate's.
Are floating floors noisy for the people below?
They can be quiet or noisy. A floating floor on a good resilient underlay, with a gap at every wall, can perform well. The same floor on thin foam, or touching the skirtings, can be noisy. NSW tribunal cases have recorded laminate floors at L'nT,w 51 to 61 on site, although supplier certificates for those floors promised better figures.
What can I do about noise from my upstairs neighbours?
Talk to them first and keep a dated record. Then ask the owners corporation or body corporate to act on the noise or floor coverings by-laws, check the dispute process and any mediation or conciliation fees in your state, and apply to the tribunal or an adjudicator if that fails. Bring objective evidence, ideally an acoustic test, because tribunals judge the noise by what an ordinary person would find unreasonable.
Does a thicker underlay always make a floor quieter?
No. The Australasian Timber Flooring Association says underlays of the same thickness can perform very differently, and the same underlay gives different results under different boards. Ask for a test report on a build-up that matches yours, including the slab and the ceiling below.
Is a creaking floor the same problem as footstep noise downstairs?
No. A creak may come from movement at a board joint or in the supporting floor. Noise downstairs concerns sound travelling through the building. Record where each sound is heard so an installer or acoustic consultant can investigate the right problem.
Sources
- NCC 2022 Volume One, Part F7 Sound transmission and insulation · Australian Building Codes Board · Accessed 2026-09-25
- NCC 2025 Volume One, Part F7 Sound transmission and insulation · Australian Building Codes Board · Accessed 2026-09-25
- NCC 2022 Volume One, Specification 28 Sound insulation for building elements · Australian Building Codes Board · Accessed 2026-09-25
- Sound Transmission and Insulation in Buildings Handbook (2022 NCC) · Australian Building Codes Board · Accessed 2026-09-25
- Guideline for Apartment and Townhouse Acoustic Rating, Version 1.0 · Association of Australasian Acoustical Consultants · Accessed 2026-09-25
- Explanatory notes regarding the impact sound insulation rating, Version 2.0 · Association of Australasian Acoustical Consultants · Accessed 2026-09-25
- AS ISO 717.2:2024 Acoustics: Rating of sound insulation in buildings and of building elements, Part 2: Impact sound insulation · Standards Australia · Accessed 2026-09-25
- Field Floor Impact Noise South-East Queensland (Australia), Inter-noise 2014 · Australian Acoustical Society · Accessed 2026-09-25
- Installation over acoustic underlays (information sheet, 21 November 2024) · Australasian Timber Flooring Association · Accessed 2026-09-25
- Body Corporate for Admiralty Towers II v Johnson [2017] QCATA 29 · Supreme Court Library Queensland · Accessed 2026-09-25
- McLeod v Body Corporate for Stradbroke Tower and Villas [2015] QCATA 146 · Supreme Court Library Queensland · Accessed 2026-09-25
- Norbury v Hogan [2010] QCATA 27 · Supreme Court Library Queensland · Accessed 2026-09-25
- 18 Kingsford Street [2016] QBCCMCmr 78 · AustLII · Accessed 2026-09-25
- Beau Monde [2011] QBCCMCmr 548 · AustLII · Accessed 2026-09-25
- Felcher v The Owners Strata Plan No 2738 [2017] NSWCATAP 219 · NSW Caselaw · Accessed 2026-09-25
- The Owners Strata Plan No 7704 v Kim [2023] NSWCATCD 39 · NSW Caselaw · Accessed 2026-09-25
- Jiang v Sui [2023] NSWCATCD 127 · NSW Caselaw · Accessed 2026-09-25
- Sui v Jiang [2024] NSWCATAP 128 · NSW Caselaw · Accessed 2026-09-25