Can a supplier's acoustic certificate show that my floor will meet the by-law?
Only if it gives the same rating your by-law uses, measured the same way, and even then it describes another building, room or laboratory set-up. In two NSW tribunal cases, floors approved on a supplier's certificate later measured worse on site: 60 and 61 L'nT,w against an approved 5 star level in Kim, and 51 and 54 against a certificate of 44 in Jiang v Sui. The AAAC says the finished floor should be tested for certainty.
What is the difference between Ln,w and L'nT,w on a test report?
Ln,w is measured in a laboratory, where the sound paths around the floor are suppressed. L'nT,w is measured in a real building, so it includes those paths, the ceiling below and the quality of the installation. Both are lower-is-better, but they are not the same measurement and cannot be compared with each other.
Can I convert an IIC or FIIC figure to L'nT,w?
Only roughly. The AAAC says either value can be subtracted from 110 to approximately indicate the other, so FIIC 65 is roughly L'nT,w 45. A Queensland field study found the two added up to between 100 and 108, so use the conversion as a range check and ask for the rating your by-law uses.
What does the ΔLw figure on an underlay data sheet tell me?
It is the laboratory improvement the underlay or covering gives on a standard bare heavy floor, and higher is better. It is not a rating for your floor, it cannot be compared with a by-law figure, and it cannot be subtracted from your building's figure, because the improvement changes with the slab, the ceiling and the floor on top.
Does the tool keep the figures I type in?
No. The tool runs in your browser and does not send or store anything you type. Use the copy or print button to keep the result.